QA Schedule Builder

Tap your department's equipment. Get a full week of quality tests: Bowie-Dick, BIs, leak tests, washer checks, foil tests. It is a CRCST exam favorite and a real SPD staple.

Step 1: what is in your department?

Toggle everything your facility runs. Weekly tests land on the day you pick below.

Step 2: pick your weekly-test day

Exam traps this tool drills into you

1. Bowie-Dick is prevacuum only

It is a Class II chemical indicator, daily, first cycle, empty chamber. Gravity steam and low-temp methods never take one.

2. BI minimum is weekly, daily is better

AAMI ST79 sets weekly as the floor per sterilizer; many departments run daily. Minimum versus best practice is a classic exam split.

3. Implants quarantine every time

Every load with implants gets a BI and the load stays out of circulation until the BI reads negative.

4. Positive BI means recall

Recall every load processed since the last negative BI. The exam loves asking how far back the recall goes.

5. Leak test is a weekly prevacuum task

The vacuum leak test checks the chamber seal, weekly, dynamic-air-removal steam only. Fail means investigate, not rerun and hope.

6. Match the BI to the process

Steam takes G. stearothermophilus. Dry heat and EO take B. atrophaeus. Swapping them is a wrong answer.

Quick answers

How often is the Bowie-Dick test run?

Daily, on each day the prevacuum steam sterilizer is used. It is the first cycle of the day and it runs in an empty chamber, because it checks the vacuum system's air removal.

How often should routine biological indicator testing be done for steam sterilizers?

AAMI ST79 calls for at least weekly BI testing per sterilizer, preferably daily. Every load that contains implants gets a BI and the load stays quarantined until the result reads negative.

Which sterilizer types need the Bowie-Dick test?

Only dynamic-air-removal (prevacuum) steam sterilizers. Gravity-displacement steam and low-temperature methods do not take a Bowie-Dick test.

How often is the vacuum leak test performed?

Weekly, on dynamic-air-removal (prevacuum) steam sterilizers. It checks whether the chamber seal holds vacuum; a failure means investigating before running loads.

How often is the ultrasonic cleaner tested?

Daily, with a foil test or commercial cavitation test. The bath is degassed before the first use of the day.

Which BI organism is used for steam versus dry heat and EO?

Steam uses Geobacillus stearothermophilus. Dry heat and ethylene oxide use Bacillus atrophaeus, because each organism matches the resistance profile of its process.

Study guidance based on AAMI ST79 guidance and standard CRCST curriculum. Your facility policy and each device's IFU always win. FunPrep is a study resource and is not affiliated with HSPA, AAMI, or any certifying body.